OBIRCH (Optical beam induced resistance change)



Optical beam induced resistance change (OBIRCH) is an imaging technique which uses a laser beam to induce a thermal change in the device. Laser stimulation highlights differences in thermal characteristics between areas containing defects and areas which are defect-free. As the laser locally heats a defective area on a metal line which is carrying a current, the resulting resistance changes can be detected by monitoring the input current to the device. OBIRCH is useful for detecting electromigration effects resulting in open metal lines.

A constant voltage is applied to the device-under-test (DUT). An area of interest is selected on the device, and a laser beam is used to scan the area. The input current being drawn by the device is monitored for changes during this process. When a change in current is noted, the position of the laser at the time that the change occurred is marked on the image of the device.

When the laser beam strikes a location which does not contain a void, good thermal transmission exists and the change in electrical resistance is small. In areas containing voids, however, thermal transmission is impeded, resulting in a larger change in resistance. The degree of resistance change is displayed visually on an image of the device, with areas of higher resistance being displayed as bright spots.

Original text: http://en.wikipedia.org/wiki/Thermal_laser_stimulation#Optical_beam_induced_resistance_change